Egyszerű nézet

dc.contributor.author Kunz P
dc.contributor.author Fellenberg J
dc.contributor.author Moskovszky, Linda
dc.contributor.author Sápi, Zoltán
dc.contributor.author Krenács, Tibor
dc.contributor.author Poeschl J
dc.contributor.author Lehner B
dc.contributor.author Szendrői, Miklós
dc.contributor.author Ewerbeck V
dc.contributor.author Kinscherf R
dc.contributor.author Fritzsching B
dc.date.accessioned 2015-07-21T07:48:41Z
dc.date.available 2015-07-21T07:48:41Z
dc.date.issued 2014
dc.identifier 84896910920
dc.identifier.citation pagination=e90727; journalVolume=9; journalIssueNumber=3; journalTitle=PLOS ONE;
dc.identifier.uri http://repo.lib.semmelweis.hu//handle/123456789/1804
dc.identifier.uri doi:10.1371/journal.pone.0090727
dc.description.abstract BACKGROUND: In osteosarcoma survival rates could not be improved over the last 30 years. Novel biomarkers are warranted to allow risk stratification of patients for more individual treatment following initial diagnosis. Although previous studies of the tumor microenvironment have identified promising candidates, novel biomarkers have not been translated into routine histopathology. Substantial difficulties regarding immunohistochemical detection and quantification of antigens in decalcified and heterogeneous osteosarcoma might largely explain this translational short-coming. Furthermore, we hypothesized that conventional hot spot analysis is often not representative for the whole section when applied to heterogeneous tissues like osteosarcoma. We aimed to overcome these difficulties for major biomarkers of the immunovascular microenvironment. METHODS: Immunohistochemistry was systematically optimized for cell surface (CD31, CD8) and intracellular antigens (FOXP3) including evaluation of 200 different antigen retrieval conditions. Distribution patterns of these antigens were analyzed in formalin-fixed and paraffin-embedded samples from 120 high-grade central osteosarcoma biopsies and computer-assisted whole-slide analysis was compared with conventional quantification methods including hot spot analysis. RESULTS: More than 96% of osteosarcoma samples were positive for all antigens after optimization of immunohistochemistry. In contrast, standard immunohistochemistry retrieved false negative results in 35-65% of decalcified osteosarcoma specimens. Standard hot spot analysis was applicable for homogeneous distributed FOXP3+ and CD8+ cells. However, heterogeneous distribution of vascular CD31 did not allow reliable quantification with hot spot analysis in 85% of all samples. Computer-assisted whole-slide analysis of total CD31- immunoreactive area proved as the most appropriate quantification method. CONCLUSION: Standard staining and quantification procedures are not applicable in decalcified formalin-fixed and paraffin-embedded samples for major parameters of the immunovascular microenvironment in osteosarcoma. Whole-slide imaging and optimized antigen retrieval overcome these limitations.
dc.relation.ispartof urn:issn:1932-6203
dc.title Osteosarcoma microenvironment: whole-slide imaging and optimized antigen detection overcome major limitations in immunohistochemical quantification.
dc.type Journal Article
dc.date.updated 2015-05-07T07:59:43Z
dc.language.rfc3066 en
dc.identifier.mtmt 2571725
dc.identifier.wos 000332468900140
dc.identifier.pubmed 24594971
dc.contributor.department SE/AOK/I/I. Sz. Patológiai és Kísérleti Rákkutató Intézet
dc.contributor.department SE/AOK/K/Ortopédiai Klinika
dc.contributor.institution Semmelweis Egyetem
dc.mtmt.swordnote PMC PMC3940945


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet