Egyszerű nézet

dc.contributor.author Tian J
dc.contributor.author Varga, Boglárka Enikő
dc.contributor.author Somfai, Gábor Márk
dc.contributor.author Lee WH
dc.contributor.author Smiddy WE
dc.contributor.author Cabrera DeBuc D
dc.date.accessioned 2015-09-09T10:32:44Z
dc.date.available 2015-09-09T10:32:44Z
dc.date.issued 2015
dc.identifier.citation pagination=e0133908; journalVolume=10; journalIssueNumber=8; journalTitle=PLOS ONE;
dc.identifier.uri http://repo.lib.semmelweis.hu//handle/123456789/2151
dc.identifier.uri doi:10.1371/journal.pone.0133908
dc.description.abstract Optical coherence tomography (OCT) is a high speed, high resolution and non-invasive imaging modality that enables the capturing of the 3D structure of the retina. The fast and automatic analysis of 3D volume OCT data is crucial taking into account the increased amount of patient-specific 3D imaging data. In this work, we have developed an automatic algorithm, OCTRIMA 3D (OCT Retinal IMage Analysis 3D), that could segment OCT volume data in the macular region fast and accurately. The proposed method is implemented using the shortest-path based graph search, which detects the retinal boundaries by searching the shortest-path between two end nodes using Dijkstra's algorithm. Additional techniques, such as inter-frame flattening, inter-frame search region refinement, masking and biasing were introduced to exploit the spatial dependency between adjacent frames for the reduction of the processing time. Our segmentation algorithm was evaluated by comparing with the manual labelings and three state of the art graph-based segmentation methods. The processing time for the whole OCT volume of 496x644x51 voxels (captured by Spectralis SD-OCT) was 26.15 seconds which is at least a 2-8-fold increase in speed compared to other, similar reference algorithms used in the comparisons. The average unsigned error was about 1 pixel ( approximately 4 microns), which was also lower compared to the reference algorithms. We believe that OCTRIMA 3D is a leap forward towards achieving reliable, real-time analysis of 3D OCT retinal data.
dc.relation.ispartof urn:issn:1932-6203
dc.title Real-Time Automatic Segmentation of Optical Coherence Tomography Volume Data of the Macular Region.
dc.type Journal Article
dc.date.updated 2015-09-03T13:04:56Z
dc.language.rfc3066 en
dc.identifier.mtmt 2935575
dc.identifier.pubmed 26258430
dc.contributor.department SE/AOK/K/Szemészeti Klinika
dc.contributor.institution Semmelweis Egyetem
dc.mtmt.swordnote PMC PMC4530974


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet