Egyszerű nézet

dc.contributor.author Nemes, Balázs
dc.contributor.author Lukacs L
dc.contributor.author Balázs, György
dc.contributor.author Dósa, Edit
dc.contributor.author Bérczi, Viktor
dc.contributor.author Hüttl, Kálmán
dc.date.accessioned 2016-04-08T11:29:08Z
dc.date.available 2016-04-08T11:29:08Z
dc.date.issued 2009
dc.identifier 67349097399
dc.identifier.citation pagination=436-440; journalVolume=32; journalIssueNumber=3; journalTitle=CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY;
dc.identifier.uri http://repo.lib.semmelweis.hu//handle/123456789/2404
dc.identifier.uri doi:10.1007/s00270-008-9501-7
dc.description.abstract Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 +/- 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 +/- 8% before the procedure to 15.7 +/- 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.
dc.relation.ispartof urn:issn:0174-1551
dc.title High-resolution CT and angiographic evaluation of NexStent wall adaptation
dc.type Journal Article
dc.date.updated 2015-11-20T10:08:11Z
dc.language.rfc3066 en
dc.identifier.mtmt 1321737
dc.identifier.wos 000266074500007
dc.identifier.pubmed 19159971
dc.contributor.department SE/AOK/K/Radiológiai és Onkoterápiás Klinika
dc.contributor.department SE/AOK/K/Kardiológia Központ - Kardiológiai Tanszék [2011.12.31]
dc.contributor.department SE/AOK/K/Érsebészeti Klinika [2011.12.31]
dc.contributor.institution Semmelweis Egyetem


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet