dc.contributor.author |
Czako, Cecilia Nóra |
|
dc.contributor.author |
Sándor, Gábor László |
|
dc.contributor.author |
Ecsedy, Mónika |
|
dc.contributor.author |
Récsán, Zsuzsanna |
|
dc.contributor.author |
Horváth, Hajnalka |
|
dc.contributor.author |
Szepessy, Zsuzsanna |
|
dc.contributor.author |
Nagy, Zoltán Zsolt |
|
dc.contributor.author |
Kovács, Illés |
|
dc.date.accessioned |
2019-08-20T11:05:15Z |
|
dc.date.available |
2019-08-20T11:05:15Z |
|
dc.date.issued |
2018 |
|
dc.identifier |
doi:10.1038/s41598-018-28994-7 |
|
dc.identifier.citation |
journalVolume=8; pagination=Paper 10598, 8 pages;
journalTitle=SCIENTIFIC REPORTS;journalAbbreviatedTitle=SCI REP; |
|
dc.identifier.other |
DOI:10.1038/s41598-018-28994-7 |
|
dc.identifier.other |
DOI:10.1038/s41598-018-28994-7 |
|
dc.identifier.uri |
http://repo.lib.semmelweis.hu//handle/123456789/7131 |
|
dc.description.abstract |
In clinical practice the measurement error of an instrument has special importance in analyzing and interpreting data, and acknowledging limitations. The purpose of this study was to evaluate intrasession and between-visit reproducibility of OCT angiography measurements in diabetic patients. A total of 54 eyes of 27 diabetic patients underwent OCT angiography imaging. Foveal avascular zone (FAZ) area and superficial retinal vessel density (VD) at 3 mm were calculated using the AngioAnalytics software. Three consecutive images were acquired at first visit and one image 1 month later. Intrasession and between-visit reproducibility of parameters were characterized by intraclass correlation coefficient (ICC), coefficient of variation (CV), and coefficient of repeatability (CR) values. We measured excellent (>0.90) ICC values both in intrasession and between-visit comparisons. CV was higher for the FAZ area compared to VD both in intrasession (7.79% vs. 2.87%) and in between-visit (12.33% vs. 2.95%) comparisons. Between-visit CR value for VD was 4.53% (95% CI: 3.72-5.79%). These data suggest that OCT angiography shows excellent repeatability in diabetic patients, indicating that this non-invasive technology might be suitable for longitudinal assessment of microvascular complications. |
|
dc.title |
Intrasession and Between-Visit Variability of Retinal Vessel Density Values Measured with OCT Angiography in Diabetic Patients |
|
dc.type |
Journal Article |
|
dc.date.updated |
2019-07-03T16:58:58Z |
|
dc.language.rfc3066 |
en |
|
dc.rights.holder |
NULL |
|
dc.identifier.mtmt |
3408508 |
|
dc.identifier.wos |
000438488500005 |
|
dc.identifier.pubmed |
30006592 |
|
dc.contributor.department |
SE/AOK/K/Szemészeti Klinika |
|
dc.contributor.institution |
Semmelweis Egyetem |
|