Egyszerű nézet

dc.contributor.author Kivovics, Márton
dc.contributor.author Szabó, Bence Tamás
dc.contributor.author Németh, Orsolya
dc.contributor.author Iványi, Dóra
dc.contributor.author Trimmel, Bálint
dc.contributor.author Szmirnova, Ilona
dc.contributor.author Orhan, Kaan
dc.contributor.author Mijiritsky, Eitan
dc.contributor.author Szabó, György
dc.contributor.author Dobó Nagy, Csaba
dc.date.accessioned 2020-03-04T13:51:58Z
dc.date.available 2020-03-04T13:51:58Z
dc.date.issued 2020
dc.identifier.citation journalVolume=9;journalIssueNumber=2;pagination=303, pages: 14;journalTitle=JOURNAL OF CLINICAL MEDICINE;journalAbbreviatedTitle=J CLIN MED;
dc.identifier.uri http://repo.lib.semmelweis.hu//handle/123456789/8159
dc.identifier.uri doi:10.3390/jcm9020303
dc.description.abstract The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.
dc.relation.ispartof urn:issn:2077-0383
dc.title Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft
dc.type Journal Article
dc.date.updated 2020-01-22T13:19:21Z
dc.language.rfc3066 en
dc.rights.holder NULL
dc.identifier.mtmt 31136992
dc.contributor.department SE/FOK/Fogászati és Szájsebészeti Oktató Intézet
dc.contributor.department SE/FOK/Orális Diagnosztikai Tanszék
dc.contributor.department SE/FOK/Arc- Állcsont- Szájsebészeti és Fogászati Klinika
dc.contributor.institution Semmelweis Egyetem


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet