dc.description.abstract INTRODUCTION: Measurement of central critical flicker-fusion frequency is a common screening test for eye diseases and additionally it can serve as a useful diagnostic test in numerous neurological and internal diseases. The test might also be used for monitoring purposes. AIM: The aim of the authors was to evaluate a digital central critical flicker-fusion frequency measuring device (IMEA ADR III) in 30 young, healthy Hungarian subjects. METHOD: After a general ophthalmological screening examination, monocular central critical flicker-fusion frequency was measured with four colours. Measurements were carried out on two separate days in three sessions under standardized conditions. Intrasession, intersession and intervisit variabilities, differences in central critical flicker-fusion frequency using the four colours and the effect of certain other influencing factors were determined. RESULTS: There were no statistically significant differences between sessions in the mean and standard deviation of the measurement sets. The central critical flicker-fusion frequency threshold for red colour was significantly lower than for other colours, and the threshold for blue colour was significantly lower than for green. There were no significant differences regarding sex, age, iris colour, and smoking indicating that these factors did not influence the central critical flicker-fusion frequency threshold in these subjects. CONCLUSIONS: Measurement results with the device are reliable and reproducible in healthy, young population in separate sessions. Orv. Hetil., 2016, 157(27), 1079-1086.
dc.relation.ispartof urn:issn:0030-6002
dc.title Az IMEA ADR III kritikus fúziós frekvenciavizsgáló eszközzel végzett mérések reprodukálhatoóságának vizsgálata
dc.type Journal Article
dc.date.updated 2016-11-15T12:25:05Z
dc.language.rfc3066 hu
dc.identifier.mtmt 3088200
dc.identifier.wos WOS:000378784600004
dc.identifier.pubmed 27346475


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet