| dc.contributor.author | Czako, Cecilia Nóra | |
| dc.contributor.author | Sándor, Gábor László | |
| dc.contributor.author | Ecsedy, Mónika | |
| dc.contributor.author | Récsán, Zsuzsanna | |
| dc.contributor.author | Horváth, Hajnalka | |
| dc.contributor.author | Szepessy, Zsuzsanna | |
| dc.contributor.author | Nagy, Zoltán Zsolt | |
| dc.contributor.author | Kovács, Illés | |
| dc.date.accessioned | 2019-08-20T11:05:15Z | |
| dc.date.available | 2019-08-20T11:05:15Z | |
| dc.date.issued | 2018 | |
| dc.identifier | doi:10.1038/s41598-018-28994-7 | |
| dc.identifier.citation | journalVolume=8; pagination=Paper 10598, 8 pages; journalTitle=SCIENTIFIC REPORTS;journalAbbreviatedTitle=SCI REP; | |
| dc.identifier.other | DOI:10.1038/s41598-018-28994-7 | |
| dc.identifier.other | DOI:10.1038/s41598-018-28994-7 | |
| dc.identifier.uri | http://repo.lib.semmelweis.hu//handle/123456789/7131 | |
| dc.description.abstract | In clinical practice the measurement error of an instrument has special importance in analyzing and interpreting data, and acknowledging limitations. The purpose of this study was to evaluate intrasession and between-visit reproducibility of OCT angiography measurements in diabetic patients. A total of 54 eyes of 27 diabetic patients underwent OCT angiography imaging. Foveal avascular zone (FAZ) area and superficial retinal vessel density (VD) at 3 mm were calculated using the AngioAnalytics software. Three consecutive images were acquired at first visit and one image 1 month later. Intrasession and between-visit reproducibility of parameters were characterized by intraclass correlation coefficient (ICC), coefficient of variation (CV), and coefficient of repeatability (CR) values. We measured excellent (>0.90) ICC values both in intrasession and between-visit comparisons. CV was higher for the FAZ area compared to VD both in intrasession (7.79% vs. 2.87%) and in between-visit (12.33% vs. 2.95%) comparisons. Between-visit CR value for VD was 4.53% (95% CI: 3.72-5.79%). These data suggest that OCT angiography shows excellent repeatability in diabetic patients, indicating that this non-invasive technology might be suitable for longitudinal assessment of microvascular complications. | |
| dc.title | Intrasession and Between-Visit Variability of Retinal Vessel Density Values Measured with OCT Angiography in Diabetic Patients | |
| dc.type | Journal Article | |
| dc.date.updated | 2019-07-03T16:58:58Z | |
| dc.language.rfc3066 | en | |
| dc.rights.holder | NULL | |
| dc.identifier.mtmt | 3408508 | |
| dc.identifier.wos | 000438488500005 | |
| dc.identifier.pubmed | 30006592 | |
| dc.contributor.department | SE/AOK/K/Szemészeti Klinika | |
| dc.contributor.institution | Semmelweis Egyetem |