| dc.contributor.author | Kivovics, Márton | |
| dc.contributor.author | Szabó, Bence Tamás | |
| dc.contributor.author | Németh, Orsolya | |
| dc.contributor.author | Iványi, Dóra | |
| dc.contributor.author | Trimmel, Bálint | |
| dc.contributor.author | Szmirnova, Ilona | |
| dc.contributor.author | Orhan, Kaan | |
| dc.contributor.author | Mijiritsky, Eitan | |
| dc.contributor.author | Szabó, György | |
| dc.contributor.author | Dobó Nagy, Csaba | |
| dc.date.accessioned | 2020-03-04T13:51:58Z | |
| dc.date.available | 2020-03-04T13:51:58Z | |
| dc.date.issued | 2020 | |
| dc.identifier.citation | journalVolume=9;journalIssueNumber=2;pagination=303, pages: 14;journalTitle=JOURNAL OF CLINICAL MEDICINE;journalAbbreviatedTitle=J CLIN MED; | |
| dc.identifier.uri | http://repo.lib.semmelweis.hu//handle/123456789/8159 | |
| dc.identifier.uri | doi:10.3390/jcm9020303 | |
| dc.description.abstract | The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability. | |
| dc.relation.ispartof | urn:issn:2077-0383 | |
| dc.title | Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft | |
| dc.type | Journal Article | |
| dc.date.updated | 2020-01-22T13:19:21Z | |
| dc.language.rfc3066 | en | |
| dc.rights.holder | NULL | |
| dc.identifier.mtmt | 31136992 | |
| dc.contributor.department | SE/FOK/Fogászati és Szájsebészeti Oktató Intézet | |
| dc.contributor.department | SE/FOK/Orális Diagnosztikai Tanszék | |
| dc.contributor.department | SE/FOK/Arc- Állcsont- Szájsebészeti és Fogászati Klinika | |
| dc.contributor.institution | Semmelweis Egyetem |