Egyszerű nézet

dc.contributor.author Csécs, Ibolya
dc.contributor.author Czimbalmos, Csilla
dc.contributor.author Suhai, Ferenc Imre
dc.contributor.author Mikle, Róbert
dc.contributor.author Mirzahosseini, Arash
dc.contributor.author Dohy, Zsófia
dc.contributor.author Szűcs, Andrea
dc.contributor.author Kiss, Anna Réka
dc.contributor.author Simor, Tamás
dc.contributor.author Tóth, Attila
dc.contributor.author Merkely, Béla Péter
dc.contributor.author Vágó, Hajnalka
dc.date.accessioned 2024-10-03T12:14:31Z
dc.date.available 2024-10-03T12:14:31Z
dc.date.issued 2018
dc.identifier 85042619243
dc.identifier.citation journalVolume=34;journalIssueNumber=7;journalTitle=INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING;pagerange=1127-1133;journalAbbreviatedTitle=INT J CARDIOVAS IMAG;
dc.identifier.uri http://repo.lib.semmelweis.hu//handle/123456789/9409
dc.identifier.uri doi:https://doi.org/10.1007/s10554-018-1322-4
dc.description.abstract While cardiac magnetic resonance (CMR) is the reference method to evaluate left and right ventricular functions, volumes and masses, there is no widely accepted method for the quantitative analysis of trabeculae and papillary muscles (TPM). The aim of this study was to investigate the effect of TPM quantification on left and right ventricular CMR values in a normal cohort and to investigate interobserver variability of threshold-based (TB) analysis by three independent observers with variant experience in CMR. At our clinic, 60 healthy volunteers (30 males, mean age 25.6 +/- 4.7 years) underwent CMR scan performed on a 1.5T Philips Achieva MR machine. On short-axis cine images, endo- and epicardial contours were detected by three independent observers with variable experience in CMR (low- ca. 120, mid- > 800, high-experienced > 5000 original CMR cases). Using Conv and TB methods (Medis 7.6 QMass software Leiden, The Netherland), we measured LV and RV ejection fractions, end-diastolic, end-systolic, stroke volumes and masses. We used TB method for quantifying TPM in ventricles using epicardial contour layers. Interobserver variability was evaluated, and the observer's experience as an impact on variability of each investigated parameters was assessed. Comparing Conv and TB quantification methods' significant difference were detected for all LV and RV parameters in case of all observers (H, M and L p < 0.0001). The global intraclass correlation coefficient (G-ICC) representing interobserver agreement for all investigated parameters was lower with Conv method (G-ICCConv vs. G-ICCTB 0.86 vs. 0.92 p < 0.0001). The ICC of LV parameters was higher using TB quantification (LV-ICCConv vs. LV-ICCTB 0.92 vs. 0.96 p < 0.0001), and for the evaluation of RV values, the TB method also had significantly higher interobserver agreement (RV-ICCConv vs. RV-ICCTB 0.80 vs. 0.89 p < 0.0001). The TB algorithm could be a consistent method to assess LV and RV CMR values, and to measure trabeculae and papillary muscles quantitatively in various level of experience in CMR.
dc.format.extent 1127-1133
dc.title Left and right ventricular parameters corrected with threshold-based quantification method in a normal cohort analyzed by three independent observers with various training-degree
dc.type Journal Article
dc.date.updated 2023-05-09T09:31:32Z
dc.language.rfc3066 en
dc.rights.holder NULL
dc.identifier.mtmt 3343164
dc.identifier.wos 000438113200015
dc.identifier.pubmed 29492774
dc.contributor.department SE/AOK/K/Városmajori Szív- és Érgyógyászati Klinika
dc.contributor.department SE/GYTK/Gyógyszerészi Kémiai Intézet
dc.contributor.institution Semmelweis Egyetem


Kapcsolódó fájlok:

A fájl jelenleg csak egyetemi IP címről érhető el.

Megtekintés/Megnyitás

Ez a rekord az alábbi gyűjteményekben szerepel:

Egyszerű nézet